Magnetic Resonance Technology: Hardware and System Component Design (New Developments in NMR, Volume 7) 🔍
Andrew G. Webb, Bruce Balcom, William Price, Steven Wright, Ralph Kimmlingen, Dennis Klomp, Christopher Collins Royal Society of Chemistry, The, Monographs in supramolecular chemistry, 16, Cambridge, 2016
英语 [en] · PDF · 9.0MB · 2016 · 📘 非小说类图书 · 🚀/lgli/lgrs/nexusstc/upload/zlib · Save
描述
There is a sharply growing interest in researchers designing and improving different hardware aspects of their magnetic resonance systems. This book covers the hardware and engineering that constitutes a magnetic resonance system, whether that be a high-resolution liquid or solid state system for NMR spectroscopy, a preclinical system for imaging animals, or a clinical system used for human imaging. Written by a team of experts in the field, this book brings the literature up to date and looks at where future developments might be.
备用文件名
nexusstc/Magnetic Resonance Technology: Hardware and System Component Design (New Developments in NMR, Volume 7)/91af0ec3124ae1052ce87b1eec8e5794.pdf
备用文件名
lgli/Webb - Magnetic Resonance Technology - Hardware and System Component Design.pdf
备用文件名
lgrsnf/Webb - Magnetic Resonance Technology - Hardware and System Component Design.pdf
备用文件名
zlib/no-category/Andrew G Webb (editor)/Magnetic Resonance Technology: Hardware and System Component Design (New Developments in NMR, Volume 7)_22038967.pdf
备选标题
Boron : sensing, synthessis and supramolecular self-assembly
备选作者
Meng Li, John S. Fossey, Tony D. James, Philip Gale, Jonathan W. Steed, Yougjun Zhang, Munenori Numata
备选作者
Andrew Webb; Bruce Balcom; William Price; Royal Society of Chemistry (Grande-Bretagne)
备选作者
Andrew Webb; Bruce Balcom; William Price; Royal Society of Chemistry (Great Britain)
备选作者
Meng Li; John S Fossey; Tony D James; Royal Society of Chemistry (Great Britain)
备选作者
Ralph Kimmlingen, Dennis Klomp, Christopher Collins, Andrew G. Webb
备选作者
Gabriel G Balint-Kurti; Alexander Palov
备选作者
Adobe Acrobat 8.1 Combine Files
备选作者
Webb, Andrew G,Price, William
备选作者
Webb, Andrew (andrew G.)
备选作者
David B Amabilino
备用出版商
Ingram Publisher Services UK- Academic
备用版本
Lightning Source Inc. (Tier 3), [Place of publication not identified], 2015
备用版本
Monographs in supramolecular chemistry, Cambridge, cop. 2016
备用版本
Lightning Source Inc. (Tier 3), [Cambridge], 2016
备用版本
United Kingdom and Ireland, United Kingdom
备用版本
New developments in NMR, Cambridge, 2016
备用版本
1, 20151103
备用版本
1, 20160427
元数据中的注释
producers:
ilovepdf.com
元数据中的注释
{"edition":"1","isbns":["1782623590","1782623876","1782628177","9781782623595","9781782623878","9781782628170"],"last_page":402,"publisher":"Royal Society of Chemistry"}
备用描述
Cover
Magnetic Resonance Technology Hardware and System Component Design
Preface
Contents
Chapter 1 - The Principles of Magnetic Resonance, and Associated Hardware
1.1 Introduction
1.2 The Superconducting Magnet and Nuclear Polarization
1.3 The Transmitter Coil to Generate Radiofrequency Pulses
1.4 Precession
1.4.1 Chemical Shift
1.4.2 Scalar Coupling
1.4.3 Relaxation Processes
1.5 The Receiver Coil for Detecting the MR Signal
1.6 The Receiver: Signal Demodulation, Digitization and Fourier Transformation
1.6.1 Receiver Electronics
1.6.2 Signal Processing
1.7 Shim Coils
1.8 Gradient Coils
1.8.1 Crusher Gradients to Dephase Transverse Magnetization
1.8.2 Gradients for Coherence Selection in High-Resolution NMR
1.8.3 Measurements of Apparent Diffusion Coefficients Using Gradients
1.8.4 Gradient-Based Shimming
1.8.5 Gradients in MRI
1.9 The Deuterium Lock Channel and Field Monitoring
1.10 Magic Angle Spinning Solid-State NMR: Principles and Instrumental Requirements
1.11 Magnetic Resonance Imaging: Principles and Instrumental Requirements
Appendices
Appendix A. Maxwell’s Equations and the Biot–Savart Law
Example A1. Magnetic Field Produced by a Straight Wire
Example A2. Magnetic Field Produced by a Circular Wire Loop
Example A3. Design of a Two-Loop Coil Geometry to Produce a Linear z-Gradient
Example A4. Design of a Two-Loop Coil Geometry to Produce a Homogeneous Magnetic Field
Appendix B. Spherical Harmonic Representation of Magnetic Fields
Visual Description
Mathematical Description of Spherical Harmonics
Example B1. Generation of a Homogeneous Magnetic Field
Example B2. Generating a Linear Magnetic Field Gradient in z
Example B3. Generating a Linear Magnetic Field Gradient in x or y
References
Chapter 2 - Magnets
2.1 Introduction
2.2 Magnet Types
2.2.1 Air-Cored Resistive Magnets
2.2.2 Permanent Magnets
2.2.3 Iron-Cored Resistive Magnets
2.2.4 Iron-Cored Superconducting Magnets
2.2.5 Superconducting Cylindrical Magnets
2.3 Magnetic Field Generation
2.3.1 Basic Physics
2.3.2 Field Homogeneity
2.3.3 Magnetic Shielding
2.3.4 System Shielding from External Interference
2.3.5 Magnetic Field Shimming
2.4 Superconductivity
2.4.1 Superconducting Materials
2.4.2 Energising a Superconducting Magnet
2.4.3 Superconducting Switch
2.4.4 Superconducting Joints
2.4.5 Quenching
2.4.6 Quench Protection
2.4.7 Stress Limits
2.5 Heat Transfer and Cryostat Design
2.5.1 Cryo-Refrigerators
2.5.2 Sub-Atmospheric Operation
2.5.3 Gradient-Induced Heating
2.6 Practical Considerations
2.6.1 Safety
2.6.2 Installation Issues
2.7 Future Developments
2.7.1 High and Ultra-High Field Magnets
2.7.2 Helium-Free Technology
References
Chapter 3 - Radiofrequency Coils
3.1 Introduction
3.2 General Electromagnetic Principles for RF Coil Design
3.2.1 Maxwell’s Equations and the Biot–Savart law
3.2.2 Transmit (B+1) and Receive (B−1) Magnetic Fields
3.2.3 Linear and Circular Polarization
3.2.4 Conservative and Non-Conservative Electric Fields
3.2.5 Electromagnetic Simulations
3.3 Electrical Circuit Analysis
3.3.1 RF Coil Impedance
3.3.2 Resonant Circuits
3.3.3 Capacitive Impedance Matching
3.3.4 Inductive Impedance Matching
3.3.5 Impedance Matching Using Transmission Line Elements
3.3.6 Baluns and Cable Traps
3.3.7 RF Coil Loading—The Effect of the Sample
3.4 RF Coils Producing a Homogeneous Magnetic Field (Volume Coils)
3.4.1 Birdcage Coils
3.4.2 Transverse Electromagnetic Mode (TEM) Resonators
3.4.3 Partial-Volume Coils
3.4.4 Solenoids and Loop Gap Resonators
3.5 Surface Coils
3.5.1 Transmit/Receive Surface Coils
3.5.2 Quadrature Surface Coils
3.6 Detuning Circuits for Transmit-Only Volume Coils and Receive-Only Surface Coils
3.7 Receive Arrays
3.7.1 Array Optimization
3.7.2 Preamplifier Decoupling in Receive Arrays
3.8 Multiple-Frequency Circuits
3.8.1 Multiple-Pole Circuits
3.8.2 Transformer Coupled Circuits
3.8.3 Multiple-Tuned Volume Coils
3.8.4 Multiple-Tuned Surface Coils
3.9 RF coils for NMR Spectroscopy
3.9.1 Probes for High Resolution Liquid-State NMR
3.9.2 Microprobes for High Resolution NMR and Hyphenated Microseparations
3.9.3 Probes for Solid-State NMR
3.9.4 Cryoprobes
3.10 RF Coils for Small Animal Imaging and MR Microscopy
3.10.1 Small Animal Imaging Coils
3.10.2 RF coils for MR Microscopy and Combined MR/Optical Histology
3.11 RF Coils for Clinical Imaging Systems
3.11.1 Single-Channel and Dual-Channel Transmit Coils for Clinical Systems
3.11.2 Receive Arrays for Clinical Systems
3.12 RF Coils for Very High Field Human Imaging
3.12.1 Multi-Channel Transmit Arrays for High Field Imaging
3.13 Dielectric Resonators
3.13.1 HEM11 Mode Resonators
3.13.2 TE01 Mode Resonators
3.14 Antennae for Travelling Wave MRI
Appendix A
Coil Workbench Measurements Using a Network Analyzer
References
Chapter 4 - B0 Shimming Technology
4.1 Introduction
4.2 The Origins of Magnetic Field Inhomogeneity
4.3 Static Spherical Harmonic Shimming
4.3.1 Theory
4.3.2 Magnetic Field Mapping
4.3.2.1 B0 Field Mapping
4.3.2.2 MRI-Based B0 Field Mapping
4.3.3 Calibration of Shim Coil Efficiency
4.3.4 Static Spherical Harmonic Shimming of the Human Brain
4.4 Dynamic Spherical Harmonic Shimming
4.4.1 Principle of Dynamic Shimming
4.4.2 Practical Considerations for Dynamic Shimming
4.4.3 Dynamic Spherical Harmonic Shimming of the Human Brain
4.5 Alternative Shimming Methods
4.5.1 Passive Approaches
4.5.2 Active Approaches
4.5.2.1 Principles and Considerations in Multicoil Shimming
4.5.2.2 Multi-Coil Shimming of the Human Brain
References
Chapter 5 - Magnetic Field Gradients
5.1 Introduction
5.1.1 Linear Magnetic Field Gradients
5.1.2 Spatial Encoding and Geometric Distortion
5.1.3 Classification of Design Methods
5.1.4 Biot–Savart Methods
5.1.4.1 Examples
5.1.5 Current Density Methods
5.1.6 Methods Using Spherical Harmonics
5.1.7 Definition of Gradient Performance Parameters
5.1.7.1 Gradient Efficiency, η, in Units of [mT A−1 m−1]
5.1.7.2 Linearity Radius rLV [m]
5.1.7.3 Slew Rate in Units of [mT m−1 ms−1]
5.1.7.4 Performance Index PI in Units of [mT2 m−2 ms−1]
5.1.8 Developments in “Conventional” Gradient Designs
5.1.9 Integrated Gradient and RF Designs
5.1.10 Increased Bore-Size Systems
5.1.11 Non-Cylindrical Designs
5.2 Gradient System
5.2.1 Overview
5.2.2 Gradient Coil System
5.2.3 Gradient Power Amplifier (GPA) and Connectors
5.2.4 Gradient Cooling System and Temperature Supervision
5.2.5 Gradient Control System and “Safety Watchdog”
5.3 Examples of Specific Gradient Coil Designs
5.3.1 High Strength Gradients for a 7 T Horizontal Bore Animal Magnet
5.3.2 A Whole-Body Modular Gradient Set with Continuously Variable Field Characteristics
5.3.3 A Head Gradient Coil Insert
5.3.4 Ultra-Strong Whole-Body Gradients
References
Chapter 6 - Radiofrequency Amplifiers for NMR/MRI
6.1 Introduction
6.2 Principles of RF Amplification
6.2.1 The RF Power MOSFET
6.2.2 DC Characteristics
6.2.3 RF Characteristics
6.2.4 Amplifier Classes
6.2.5 Switch-Mode Amplifiers
6.2.6 Mechanism of RF Power Amplification
6.3 Matching Networks for Amplifiers
6.3.1 Basics of Matching Networks
6.3.2 Narrowband Matching
6.3.3 Broadband Matching
6.4 Amplifier Performance Considerations
6.4.1 Linearity
6.4.2 Noise Gating
6.4.3 Dynamic Range
6.4.4 Efficiency
6.4.5 Stability
6.4.6 Technical Specifications for Commercial RFPAs for MRI
6.5 Amplifiers for Multi-Channel Transmission
6.5.1 Mutual Coupling in Transmit Arrays
6.6 Current Source Amplifiers
6.6.1 Matching Networks for Current Source Amplifiers
6.6.2 Analysis of the Current Source Network
6.7 Low Output Impedance Amplifiers
6.7.1 Coil Matching Network for an LOI amplifier
6.8 Testing and Comparison of Amplifiers Architectures
6.8.1 Amplifier Bench Measurements
6.8.2 Amplifier Testing Using MRI
6.9 Selection of Amplifier Architecture
References
Chapter 7 - The MR Receiver Chain
7.1 Introduction
7.2 Signal Levels and Dynamic Ranges of MR Data
7.3 Overall Noise Figure of the Receive Chain
7.4 Design of Transmit/Receive Switches
7.5 Low-Noise Preamplifiers
7.6 Data Sampling
7.6.1 Frequency Demodulation
7.6.2 Direct Detection Using Undersampling
7.7 Analogue-to-Digital Converters
7.8 Optical and Wireless Data Transmission
References
Chapter 8 - Electromagnetic Modelling
8.1 Introduction
8.2 Simulating Electromagnetic Fields for Magnetic Resonance
8.2.1 Static Magnetic (B0) Fields
8.2.2 Switched Gradient Fields (Gx, Gy, Gz)
8.2.3 Radiofrequency Magnetic (B1) Fields
8.2.3.1 Analytically Based Methods
8.2.3.2 Finite Difference Time Domain (FDTD) Method
8.2.3.3 Finite Element Method (FEM)
8.2.3.4 Method of Moments
8.2.3.5 Hybrid Simulation Methods
8.2.3.6 Approaches Using Multiple “Ideal” Current or Voltage Sources
8.2.3.7 Circuit Co-Simulation
8.3 The Role of Simulations in Assessing MR Safety and Bioeffects
8.3.1 Static Field Effects
8.3.2 Gradient-Induced Peripheral Nerve Stimulation (PNS)
8.3.3 RF-Induced Heating in the Human Body
8.3.4 Safety of Devices and Implants
8.3.5 MR Safety in Practice
8.4 Calculating the Effects of Electromagnetic Fields on MR Images
8.4.1 Calculation of the Intrinsic Signal-to-Noise Ratio (ISNR)
8.4.2 Simulating MR Images
8.5 Methods for Validating Simulations
Acknowledgements
References
Subject Index
备用描述
Magnetic Resonance Systems Are Used In Almost Every Academic And Industrial Chemistry, Physics And Biochemistry Department, As Well As Being One Of The Most Important Imaging Modalities In Clinical Radiology. The Design Of Such Systems Has Become Increasingly Sophisticated Over The Years. Static Magnetic Fields Increase Continuously, Large-scale Arrays Of Receive Elements Are Now Ubiquitous In Clinical Mri, Cryogenic Technology Has Become Commonplace In High Resolution Nmr And Is Expanding Rapidly In Preclinical Mri, Specialized High Strength Magnetic Field Gradients Have Been Designed For Studying The Human Connectome, And The Commercial Advent Of Ultra-high Field Human Imaging Has Required New Types Of Rf Coils And Static Shim Coils Together With Extensive Electromagnetic Simulations To Ensure Patient Safety.this Book Covers The Hardware And Engineering That Constitutes A Magnetic Resonance System, Whether That Be A High-resolution Liquid Or Solid State System For Nmr Spectroscopy, A Preclinical System For Imaging Animals Or A Clinical System Used For Human Imaging. Cover; Magnetic Resonance Technology Hardware And System Component Design; Preface; Contents; Chapter 1 -- The Principles Of Magnetic Resonance, And Associated Hardware; Chapter 2 -- Magnets; Chapter 3 -- Radiofrequency Coils; Chapter 4 -- B0 Shimming Technology; Chapter 5 -- Magnetic Field Gradients; Chapter 6 -- Radiofrequency Amplifiers For Nmr/mri; Chapter 7 -- The Mr Receiver Chain; Chapter 8 -- Electromagnetic Modelling; Subject Index; 1.1 Introduction; 1.2 The Superconducting Magnet And Nuclear Polarization; 1.3 The Transmitter Coil To Generate Radiofrequency Pulses; 1.4 Precession 1.5 The Receiver Coil For Detecting The Mr Signal1.6 The Receiver: Signal Demodulation, Digitization And Fourier Transformation; 1.7 Shim Coils; 1.8 Gradient Coils; 1.9 The Deuterium Lock Channel And Field Monitoring; 1.10 Magic Angle Spinning Solid-state Nmr: Principles And Instrumental Requirements; 1.11 Magnetic Resonance Imaging: Principles And Instrumental Requirements; Appendices; Appendix A. Maxwell's Equations And The Biot-savart Law; Appendix B. Spherical Harmonic Representation Of Magnetic Fields; References; 2.1 Introduction; 2.2 Magnet Types; 2.3 Magnetic Field Generation 2.4 Superconductivity2.5 Heat Transfer And Cryostat Design; 2.6 Practical Considerations; 2.7 Future Developments; References; 3.1 Introduction; 3.2 General Electromagnetic Principles For Rf Coil Design; 3.3 Electrical Circuit Analysis; 3.4 Rf Coils Producing A Homogeneous Magnetic Field (volume Coils); 3.5 Surface Coils; 3.6 Detuning Circuits For Transmit-only Volume Coils And Receive-only Surface Coils; 3.7 Receive Arrays; 3.8 Multiple-frequency Circuits; 3.9 Rf Coils For Nmr Spectroscopy; 3.10 Rf Coils For Small Animal Imaging And Mr Microscopy; 3.11 Rf Coils For Clinical Imaging Systems 3.12 Rf Coils For Very High Field Human Imaging3.13 Dielectric Resonators; 3.14 Antennae For Travelling Wave Mri; Appendix A; References; 4.1 Introduction; 4.2 The Origins Of Magnetic Field Inhomogeneity; 4.3 Static Spherical Harmonic Shimming; 4.4 Dynamic Spherical Harmonic Shimming; 4.5 Alternative Shimming Methods; References; 5.1 Introduction; 5.2 Gradient System; 5.3 Examples Of Specific Gradient Coil Designs; References; 6.1 Introduction; 6.2 Principles Of Rf Amplification; 6.3 Matching Networks For Amplifiers; 6.4 Amplifier Performance Considerations 6.5 Amplifiers For Multi-channel Transmission6.6 Current Source Amplifiers; 6.7 Low Output Impedance Amplifiers; 6.8 Testing And Comparison Of Amplifiers Architectures; 6.9 Selection Of Amplifier Architecture; References; 7.1 Introduction; 7.2 Signal Levels And Dynamic Ranges Of Mr Data; 7.3 Overall Noise Figure Of The Receive Chain; 7.4 Design Of Transmit/receive Switches; 7.5 Low-noise Preamplifiers; 7.6 Data Sampling; 7.7 Analogue-to-digital Converters; 7.8 Optical And Wireless Data Transmission; References; 8.1 Introduction; 8.2 Simulating Electromagnetic Fields For Magnetic Resonance Editors: Andrew G. Webb, Bruce Balcom, William Price. Includes Bibliographical References And Index.
备用描述
This publication covers the hardware and engineering that constitutes a magnetic resonance system, whether that be a high-resolution liquid or solid state system for NMR spectroscopy, a preclinical system for imaging animals, or a clinical system used for human imaging. Magnetic resonance systems are used in almost every academic and industrial chemistry, physics and biochemistry department, as well as being one of the most important imaging modalities in clinical radiology. The design of such systems has become increasingly sophisticated over the years. Static magnetic fields increase continuously, large-scale arrays of receive elements are now ubiquitous in clinical MRI, cryogenic technology has become commonplace in high resolution NMR and is expanding rapidly in preclinical MRI, specialized high strength magnetic field gradients have been designed for studying the human connectome, and the commercial advent of ultra-high field human imaging has required new types of RF coils and static shim coils together with extensive electromagnetic simulations to ensure patient safety. This book covers the hardware and engineering that constitutes a magnetic resonance system, whether that be a high-resolution liquid or solid state system for NMR spectroscopy, a preclinical system for imaging animals or a clinical system used for human imaging. Written by a team of experts in the field, this book provides a comprehensive and instructional look at all aspects of current magnetic resonance technology, as well as outlooks for future developments
备用描述
<P>The ability to monitor analytes within physiological, environmental, and industrial scenarios is of prime importance in many scenarios. Chemists have striven to mimic nature’s ability to produce robust chemosensors with the capacity to detect molecules and signal their presence. The covalent coupling interaction between boronic acids and saccharides has been exploited to monitor saccharides. The boronic acid–and Lewis acid base interaction is also suitable for the capture and recognition of anions, which are involved in fundamental processes in all living things.</P><P>There have been significant advances in the field of boronic acid based receptors and this book provides a comprehensive overview and update on the topic. Not only are the applications of boron in chemical molecular sensors covered in detail, but their synthesis and supramolecular self-assembly are also presented. Topics include: the molecular recognition of saccharides, the complexation of boronic acids with saccharides, fluorescent sensors and the modular construct of fluorescent sensors, further sensory systems for saccharide recognition and an extensive bibliography.</P><P>Edited by experts in the area and containing international contributions from leading research groups on the subject, this book provides a useful resource for graduate students, academic and industrial researchers in organic chemistry, supramolecular chemistry, materials science and bio-organic chemistry.</P>
备用描述
The ability to monitor analytes within physiological, environmental, and industrial scenarios is of prime importance in many scenarios. Chemists have striven to mimic nature's ability to produce robust chemosensors with the capacity to detect molecules and signal their presence. The covalent coupling interaction between boronic acids and saccharides has been exploited to monitor saccharides. The boronic acid–and Lewis acid base interaction is also suitable for the capture and recognition of anions, which are involved in fundamental processes in all living things. There have been significant advances in the field of boronic acid based receptors and this book provides a comprehensive overview and update on the topic. Not only are the applications of boron in chemical molecular sensors covered in detail, but their synthesis and supramolecular self-assembly are also presented. Topics include: the molecular recognition of saccharides, the complexation of boronic acids with saccharides, fluorescent sensors and the modular construct of fluorescent sensors, further sensory systems for saccharide recognition and an extensive bibliography. Edited by experts in the area and containing international contributions from leading research groups on the subject, this book provides a useful resource for graduate students, academic and industrial researchers in organic chemistry, supramolecular chemistry, materials science and bio-organic chemistry.
备用描述
The ability to monitor analytes within physiological, environmental, and industrial scenarios is of prime importance in many scenarios. Chemists have striven to mimic nature2s ability to produce robust chemosensors with the capacity to detect molecules and signal their presence. The covalent coupling interaction between boronic acids and saccharides has been exploited to monitor saccharides. The boronic acid and Lewis acid base interaction is also suitable for the capture and recognition of anions, which are involved in fundamental processes in all living things. There have been significant advances in the field of boronic acid based receptors and this book provides a comprehensive overview and update on the topic. Not only are the applications of boron in chemical molecular sensors covered in detail, but their synthesis and supramolecular self-assembly are also presented. Topics include: the molecular recognition of saccharides, the complexation of boronic acids with saccharides, fluorescent sensors and the modular construct of fluorescent sensors, further sensory systems for saccharide recognition and an extensive bibliography. Edited by experts in the area and containing international contributions from leading research groups on the subject, this book provides a useful resource for graduate students, academic and industrial researchers in organic chemistry, supramolecular chemistry, materials science and bio-organic chemistry
备用描述
<P>Magnetic resonance systems are used in almost every academic and industrial chemistry, physics and biochemistry department, as well as being one of the most important imaging modalities in clinical radiology. The design of such systems has become increasingly sophisticated over the years. Static magnetic fields increase continuously, large-scale arrays of receive elements are now ubiquitous in clinical MRI, cryogenic technology has become commonplace in high resolution NMR and is expanding rapidly in preclinical MRI, specialized high strength magnetic field gradients have been designed for studying the human connectome, and the commercial advent of ultra-high field human imaging has required new types of RF coils and static shim coils together with extensive electromagnetic simulations to ensure patient safety.</P><P>This book covers the hardware and engineering that constitutes a magnetic resonance system, whether that be a high-resolution liquid or solid state system for NMR spectroscopy, a preclinical system for imaging animals or a clinical system used for human imaging. Written by a team of experts in the field, this book provides a comprehensive and instructional look at all aspects of current magnetic resonance technology, as well as outlooks for future developments.</P>
备用描述
Magnetic Resonance Technology: Hardware and System Component Design, 2016, pp. 440, 978-1-78262-212-3
开源日期
2022-07-18
更多信息……

🚀 快速下载

成为会员以支持书籍、论文等的长期保存。为了感谢您对我们的支持,您将获得高速下载权益。❤️

🐢 低速下载

由可信的合作方提供。 更多信息请参见常见问题解答。 (可能需要验证浏览器——无限次下载!)

所有选项下载的文件都相同,应该可以安全使用。即使这样,从互联网下载文件时始终要小心。例如,确保您的设备更新及时。
  • 对于大文件,我们建议使用下载管理器以防止中断。
    推荐的下载管理器:JDownloader
  • 您将需要一个电子书或 PDF 阅读器来打开文件,具体取决于文件格式。
    推荐的电子书阅读器:Anna的档案在线查看器ReadEraCalibre
  • 使用在线工具进行格式转换。
    推荐的转换工具:CloudConvertPrintFriendly
  • 您可以将 PDF 和 EPUB 文件发送到您的 Kindle 或 Kobo 电子阅读器。
    推荐的工具:亚马逊的“发送到 Kindle”djazz 的“发送到 Kobo/Kindle”
  • 支持作者和图书馆
    ✍️ 如果您喜欢这个并且能够负担得起,请考虑购买原版,或直接支持作者。
    📚 如果您当地的图书馆有这本书,请考虑在那里免费借阅。